TY - UNPB AV - public N2 - A study was conducted for comparative evaluation of atomic absorption spectrophotometry (AAS) and inductively coupled plasma?optical emission spectroscopy (ICP-OES) for determining extractable zinc (Zn), copper (Cu), manganese (Mn), and iron (Fe) in sixty diverse soil samples having a wide range in pH and organic carbon (C). The results were significantly affected by the method of analysis and soil type but generally did not follow a definite trend. Results for extractable Fe in Alfisol samples were significantly greater when using ICP-OES than AAS; and the results for Zn, Cu, and Mn were not significantly different for the two methods. For Vertisol samples, the results for extractable Cu were significantly greater by ICP-OES than by AAS, whereas extractable Fe and Zn were significantly greater by AAS than by ICP-OES, and the results for Mn were not significantly different for the two methods. The results are discussed relative to soil type and differences in soil organic carbon and pH of the samples used in the study. UR - http://dx.doi.org/10.1080/00103624.2015.1005226 SP - 627 Y1 - 2015/// EP - 632 PB - Taylor & Francis TI - Comparative Evaluation of Inductively Coupled Plasma?Optical Emission Spectroscopy and Atomic Absorption Spectrophotometry for Determining DTPA-Extractable Micronutrients in Soils ID - icrisat8590 A1 - Sunitha, M A1 - Sahrawat, K L A1 - Wani, S P KW - Alfisols KW - extractable Fe KW - Cu KW - Mn KW - and Zn KW - soil testing KW - Vertisol and associated soils SN - 0010-3624 JF - Communications in Soil Science and Plant Analysis VL - 46 ER -